Oman · Seawater and brackish elements
RO Membranes Supplier in Oman
Aqua Flair Trading LLC, in Dubai, quotes RO membranes to buyers in Oman. Ten elements are listed, seawater and brackish, in 4040 and 8040 sizes, each with its listed flow per day.
Supplied from Dubai, UAE
RO Membranes
Oman Observer reports that desalination covers about 86% of needs. Zawya, citing the 2026 to 2032 PWP statement, describes the newer large plants as RO-dominated. A small hotel, farm or factory skid uses the same elements on a smaller scale.
Tell us the feed water, the output you want and the vessels you have.
How we support your project
- Ten membrane elements, seawater and brackish • 4040 and 8040 sizes • Listed flow per element, in m³/day • Count worked out from feed and output • A quotation by element and quantity
Ideal for
- Seawater RO skids at the coast • Brackish well RO in the Batinah and interior • Replacement elements for existing vessels • Hotels, farms and factories running their own plant • Contractors building new skids
RO Membrane
Filmtec BW30 PRO-4040
View DetailFilmtec SW30-4040
View DetailFilmtec SW30 HRLE-400
View DetailHydranautics CPA3 8040
View DetailHydranautics SWC5-LD
View DetailLG BW 400 R
View DetailLG BW 4040 R
View DetailLG SW 400 R
View DetailRefurbished / Used RO Membranes
Available Brands: Toray and Hydranautics, refurbished with care Available Sizes: 8040 (8″×40″) Available Models: Toray TM820 440/400, Hydrnautics SWC6 Max Origin: USA, JAPAN, KSA
View DetailProduct Detail
Water treatment equipment we supply alongside RO Membrane in Oman
A membrane lives in a vessel and depends on clean, dosed feed. Oman pages we pair with it:
• RO pressure vessels that hold the elements
• refurbished RO membranes for a lower-cost swap
• cartridge filters as the guard stage
• cation resin to remove hardness ahead of brackish RO
• dosing tanks for antiscalant
• FRP vessels for the media filters ahead
LG BW 4040 R supply for Oman
Each card shows a listed flow per element in m³ a day. Divide the output you need by that figure and round up.
Two sizing examples
The listed flow is a ceiling reached under test conditions. In real service, cold, salty or fouled water gives less, so a designer often adds elements. Use these as a first count only.
A 200 m³/d seawater unit
|
Element |
Listed flow |
Elements needed |
|
SW30 HRLE-400 |
28.4 m³/d |
200 ÷ 28.4 = 7.04, so 8 |
|
SWC5-LD |
34.1 m³/d |
200 ÷ 34.1 = 5.9, so 6 |
|
LG SW 400 R |
34.1 m³/d |
200 ÷ 34.1 = 5.9, so 6 |
A 150 m³/d brackish unit
|
Element |
Listed flow |
Elements needed |
|
BW30 PRO-400 |
41.6 m³/d |
150 ÷ 41.6 = 3.6, so 4 |
|
LG BW 400 R |
39.7 m³/d |
150 ÷ 39.7 = 3.8, so 4 |
|
BW30 PRO-4040 |
9.1 m³/d |
150 ÷ 9.1 = 16.5, so 17 |
The 4040 element is smaller, so a plant of this size needs many more of them. Use 4040 elements for small skids and 8040 for larger ones.
Why two passes at the big plants. DuPont’s case study of the Barka plant (281,000 m³/d) describes a first pass of seawater elements at 46% recovery and a second pass of brackish-type elements at 85%. Seawater there is 42,000 to 43,000 ppm TDS, with boron at 5.6 ppm, at 22 to 35 °C. Product is below 420 ppm TDS and below 2.4 ppm boron. The second pass polishes the first, mainly for boron and salinity. A small skid usually does not need one. Ask your designer.
Feed temperature matters. Warm water passes more flow through a membrane than cold. A 35 °C intake yields more than a 22 °C one, so the same element count behaves differently across the seasons.
Guard before you grow. Fouled membranes lose flow. Pair the elements with a cartridge stage and an antiscalant dose.
Procurement value
Why teams in Oman source through Aqua Flair
Aqua Flair ships RO membranes and vessels from Dubai to Oman and across the region. List the elements, the vessels and the guard filters, and one itemised price comes back. The rest of the range sits under water treatment equipment supplier in Oman, and you can read who is behind the quotation on the Aqua Flair Trading LLC page.
• Per-element pricing
Each model is its own line.
• Data sheets
Product pages hold them for submittals.
• Route from Dubai
Agreed with you once quantity and town are fixed.
• Spare set
Price a second set with the first.
Our approach
What we stand for
Three facts give a first count.
1. Feed
sea, brackish or tap, with TDS and temperature. Prefer to talk first? Reach our technical team.
2. Output
m³ per day.
3. Count
elements per vessel and vessels per skid.
Deployment
Applications for RO Membrane in Oman
Coastal hotels, island camps, factories in Sohar and Sur, farm wells in the Batinah and compounds in the interior run RO. We supply the elements. Operators fit them to vessels.
Utilities & bulk water
- Seawater RO / Brackish RO / Replacement sets
Industrial applications
- Food and drink / Power-site make-up / Process water
Commercial & institutional
- Hotels / Hospitals / Farms
Regional project support
Quotation and supply coordination for buyers serving Oman.
Element count
We turn your output into an element list.
Dispatch plan
Dubai to your Omani town, agreed before the order.
Range
More products sit under the Our Products button, and every family has its own page in the product categories.
Joint quotation
Elements, vessels and filters together.
Get in touch
Send us your inquiry
Give the feed type and TDS, the output per day, the element size, the quantity and the Omani town.
Call/Whatsapp
+971 50 744 0236Visit us